Frequent maintenance intervals for vehicles and machines are associated with high cost for fleet operators. Therefore owners are constantly looking for saving potentials. A trigger for shortened maintenance intervals are long idle times of engines. In order to reduce useless idling the automatic engine shutdown DYNTEST IdleControl is ideally suited. This automatic engine stop can be used as a standalone solution or pre-installed with the ControlBox.
IdleControl works independently of the combustion process and is therefore suitable for diesel and gas engines.

  • IdleControl - automatic idle limiter

IdleControl - automatic idle limiter

By shutting down the engine in idle mode, fuel is saved and the environment is protected. The installation of DYNTEST IdleControl ensures that the engines are switched off automatically in areas where they are not permitted to run in idle mode for an extended period of time. This becomes more and more obligatory due to regulations or laws. Fuel consumption and harmful exhaust gases are reduced significantly DYNTEST IdleControl works independently of the combustion process and can thus be installed in both diesel and gas engines. Additionally to the shutdown function the system records the operating data and the shutdown events. The data can -as known from the DYNTEST Control-Box- be read out and analyzed via PC using the CPK terminal software. The preset parameters for the shutdown function can also be modified.

Technical data

  • Ambient temperature: -20 - + 80° C
  • Supply voltage: 10 - 30 V DC
  • Current in operation: 50 - 250 mA
  • Current standby: 1 mA
  • Protection type: IP64
  • Memory: 16 MB
  • Dimension: 95 x 100 x 38 mm
  • Electrical protection: Overvoltage
  • EMC protection: Supressed against outgoing electrical interference
  • Versions: 12V / 24V
  • Buzzer: 85dB

DYNTEST IdleControl can be used in different ways

  • DYNTEST IdleControl can be installed as stand-alone solution
  • An Integration in the tried and tested DYNTEST DPF-Monitoring system (ControlBox V4) is easily possible

 

More information:

Flyer

 

 

About the functions of DYNTEST IdleControl:

A countdown sequence starts as soon as the parking brake is activated while idling. After a preset time an acoustic signal alerts the user that the engine will be switched off shortly. After reaching the shutdown time, DYNTEST IdleControl turns off the engine automatically.
In order to ensure that the engine keeps running at very high or very low ambient temperatures a temperature sensor can be installed optionally. This guarantees that the DYNTEST IdleControl switches off the engine only at ambient temperatures within a certain range. For example between 10 and 27 ° C (this temperature range can also be parameterized). This allows the engine to operate at very low temperatures for heating or at very high temperatures for cooling. Within the predetermined temperature range the engine is switched off automatically for example after five minutes idling with active park brake (also calibratable).

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.